Skip to main content

Radial fans

Plastic radial fans for conveying chemically aggressive exhaust air

The HLU radial fans made of plastic are specially designed for conveying chemically aggressive exhaust air. They are characterized by the highest level of corrosion resistance. They also achieve high volume flows and pressure differences with optimum efficiency. The radial fans are considered efficient “all-rounders” among plastic fans. The HLU offers you tailor-made solutions for your needs, from standard products to individual special solutions. For use in potentially explosive areas, all series are available in explosion-proof versions in accordance with ATEX for Zones 2 and 1.

Small radial fans

HF R 75/110

Application

  • Can be used in all applications with small air volumes
  • Low weight and compact dimensions ensure easy installation
  • ideal for 24-hour exhaust air from chemical storage cabinets
  • optionally suitable for installation and extraction from ATEX Zone 2 and 1

characteristics

  • Volume flow from 15 – 500 m³/h
  • at a maximum pressure difference of 420 Pa
  • Available in nominal widths of 75 and 110 mm
Volume flow 15 – 500 m³/h
maximum pressure difference 420 Pa
Nominal diameters 75 and 110mm
operating temperatur 0 – 60 °C
Housing material PPs-el
Impeller material PPs-el
drive Three-phase or alternating current motor
Atex Suitable as standard for installation and extraction from ATEX Zone 2, optionally for ATEX Zone 1 in electrically conductive version
execution with shaft seal as standard
Connection options Pipe or flange connection

Advantages:

corrosion-resistant
compact design
Variants for different installation situations
Fast availability of standard variants
Engine outside the airflow
Use of different motors (Ex-motors) possible

Radial fans

HF R15/17

Application

  • Can be used in all applications with medium air volumes
  • ideal for extraction of fumes and chemical cabinets in laboratories
  • with optional accessories also suitable for more demanding industrial applications, such as the extraction of baths in the electroplating industry
  • optionally suitable for installation and extraction from ATEX Zone 2 and 1

characteristics

  • Volume flow from 100 – 15,000 m³/h
  • at a maximum pressure difference of 5,000 Pa
  • Available in 12 nominal sizes from 125 – 500 mm suction diameter
Volume flow 100 – 15,000 m³/h
maximum pressure difference 5,000 Pa
Efficiency up to 81%
Nominal diameters 12 nominal diameters from 125 – 500 mm
operating temperatur 0 – 60 °C
Housing material UV-resistant PEs
Impeller material PPs, GRP, CFRP
drive Direct or belt drive
Atex Optionally suitable for installation and extraction from ATEX Zone 2 or ATEX Zone 1 in electrically conductive version
Connection options Pipe or flange connection

Advantages:

corrosion-resistant
energy efficient
weatherproof
compact design
finely graduated sizes
Fast availability of standard variants
Suction and pressure sides with the same diameters
extensive range of accessories
Engine outside the airflow
Use of different motors (Ex-motors) possible

VIEW CATALOGUE

Radial fans with EC motor

HF R 15/17 EC

Application

  • ideal for energy-sensitive applications and modernization measures
  • optionally suitable for installation and extraction from ATEX Zone 24

characteristics

  • Volume flow from 100 – 3,000 m³/h
  • at a maximum pressure difference of 1,600 Pa
  • Available in 6 nominal widths from 125 – 250 mm
  • Simplest speed control through EC motor with integrated control electronics
  • Optional control via external 0 – 10 volt signal or Modbus interface possible
Volume flow 100 – 3,000 m³/h
maximum pressure difference 1,600 Pa
Efficiency up to 81%
Nominal diameters 6 nominal diameters from 125 – 250 mm
operating temperatur 0 – 60 °C
Housing material UV-resistant PEs
Impeller material PPs
drive energy-efficient EC motor
Atex optionally suitable for installation and extraction from ATEX Zone 2
execution Speed ​​controller and repair switch fully wired
Connection options Pipe or bottle connection

Advantages:

easy and safe to use and install
easy connection (plug & play)
High efficiency
low energy consumption
optimally integrated monitoring function
Speed ​​continuously adjustable
compact design
no additional parts required

VIEW CATALOGUE

Radial fans

HF R13/16

Application

  • Can be used in all applications with large air volumes, such as electroplating baths, semiconductor industry, water treatment plants and special process exhaust air applications
  • Ideal for extracting collective exhaust air from large laboratories at universities, research institutes and in the chemical industry
  • Due to the wide range of possible materials for the housings and impellers, they can be optimally configured to meet specific requirements
    optionally suitable for installation and extraction from ATEX Zone 2 and 1

characteristics

  • Volume flow from 3,000 – 250,000 m³/h
  • at a maximum pressure difference of > 5,000 Pa
  • Available in 18 nominal sizes from 160 – 1,600 mm suction diameter
Volume flow 3,000 – 250,000 m³/h
maximum pressure difference >5,000 Pa
Efficiency up to 81%
Nominal diameters 18 nominal diameters from 160 – 1,600 mm
operating temperatur 0 – 70 °C
Housing material PPs
Impeller material PPs, GRP, CFRP, steel-coated
drive Direct, belt or clutch drive
Atex optionally suitable for extraction from ATEX Zone 2 or ATEX Zone 1 in electrically conductive version
execution Frame galvanized as standard
Connection options Pipe or flange connection

Advantages:

corrosion-resistant
High efficiency
Engine outside the airflow
Use of different motors (Ex-motors) possible

VIEW CATALOGUE

High pressure radial fan

HF R48

Application

  • to achieve high pressures at low volume flow
  • ideal for applications with sniffer exhaust air, multi-stage exhaust air purification, liquid baths and many special applications of process exhaust air
  • Due to the wide range of possible materials for the housings and impellers, they can be optimally configured to meet specific requirements
  • optionally suitable for installation and extraction from ATEX Zone 2 and 1

characteristics

  • Volume flow from 100 – 7,000 m³/h
  • at a maximum pressure difference of > 7,000 Pa
  • Available in 7 nominal sizes from 50 – 200 mm suction diameter
Volume flow 100 – 7,000 m³/h
maximum pressure difference 7,000 Pa
Efficiency up to 60%
Nominal diameters 7 nominal diameters from 50 – 200 mm
operating temperatur 0 – 70 °C
Housing material PPs
Impeller material Steel coated
drive Belt drive
Atex optionally suitable for extraction from ATEX Zone 2 or ATEX Zone 1 in electrically conductive version

Advantages:

corrosion-resistant
High pressure version up to 7,000 Pa
no metal parts in the air stream
Engine outside the airflow
Use of different motors (Ex-motors) possible

High pressure radial fan

RV20

Application

  • Can be used in all applications with medium air volumes
  • ideal for extraction with high pressure differences
  • with optional accessories also suitable for more demanding industrial applications, such as the extraction of baths in the electroplating industry
  • optionally suitable for installation and extraction from ATEX Zone 2 and 1

characteristics

  • Volume flow of 80 – 2,500 m³/h at a maximum pressure difference of >6,500 Pa
  • Available in 4 nominal sizes from 80 – 140 mm suction diameter
Volume flow 80 – 2,500 m³/h
maximum pressure difference 6,500 Pa
Efficiency up to 76%
Nominal diameters 4 nominal diameters from 80 – 140 mm
operating temperatur 0 – 60 °C
Housing material PP, PPs, PVC, PE, PVDF
Impeller material PP, PPs, PVC, PVDF, GFK, CFK, steel-coated
drive Direct or belt drive
Atex Optionally suitable for installation and extraction from ATEX Zone 2 or ATEX Zone 1 in electrically conductive version
Connection options Pipe or flange connection

Advantages:

corrosion-resistant
High pressure version up to 6,500 Pa
no metal parts in the air stream
Engine outside the airflow
Use of different motors (Ex-motors) possible

High pressure radial fan

RV28

Application

  • Can be used in all applications with medium and high air volumes
  • ideal for extraction with high pressure differences
  • with optional accessories also suitable for more demanding industrial applications, such as the extraction of baths in the electroplating industry
  • optionally suitable for installation and extraction from ATEX Zone 2 and 1

characteristics

  • Volume flow from 500 – 50,000 m³/h
  • at a maximum pressure difference of > 6,000 Pa
  • Available in 13 nominal sizes from 200 – 800 mm suction diameter
Volume flow 500 – 50,000 m³/h
maximum pressure difference 6,000 Pa
Efficiency up to 71%
Nominal diameters 13 nominal diameters from 200 – 800 mm
operating temperatur 0 – 60 °C
Housing material PP, PPs, PVC, PE, PVDF
Impeller material PP, PPs, PVC, PVDF, GFK, CFK, steel-coated
drive Direct or belt drive
Atex Optionally suitable for installation and extraction from ATEX Zone 2 or ATEX Zone 1 in electrically conductive version
Connection options Pipe or flange connection

Advantages:

corrosion-resistant
High pressure version up to 6,000 Pa
no metal parts in the air stream
Engine outside the airflow
Use of different motors (Ex-motors) possible

Overview of possible housing positions